Cyber Essentials password requirements (v3.3, 2026)
Cyber Essentials v3.3 password rules: MFA, or a 12-character minimum, or 8 characters with a deny list, no maximum length, and no more than 10 guesses in 5 minutes.
Cyber Essentials v3.3 requires a technical control on password quality: MFA, a minimum length of 12 characters, or a minimum of 8 characters with automatic blocking of common passwords, always with no maximum length. Passwords must also resist brute force through MFA, throttling to no more than 10 guesses in 5 minutes, or locking after 10 failed attempts.
- Quality (one of)
- MFA; a minimum of 12 characters; or a minimum of 8 characters with a deny list of common passwords. No maximum length in any case
- Brute force (at least one of)
- MFA; throttling to no more than 10 guesses in 5 minutes; locking after no more than 10 unsuccessful attempts
- Do not enforce
- Regular password expiry or password complexity requirements
- Device unlock only
- A biometric, or a PIN or password of at least 6 characters, protected against brute force (Secure Configuration)
- Automatic fail?
- None of the password questions carries fail wording. In our assessments a non-compliant answer is returned for correction
- What changed in 2026
- The thresholds are unchanged in v3.3. FIDO2 is named under passwordless, and option D in A4.3 and A5.5 is passwordless with a notes field
What are the Cyber Essentials password rules?
The scheme requires one of three options, enforced technically: MFA, a 12-character minimum, or an 8-character minimum with a deny list of common passwords, each with no maximum length.
Use technical controls to manage the quality of passwords. This will include one of the following: Using multi-factor authentication; A minimum password length of at least 12 characters, with no maximum length restrictions; A minimum password length of at least 8 characters, with no maximum length restrictions and use automatic blocking of common passwords using a deny list
'Technical control' means the system refuses a password that breaks the rule: the Entra ID password policy, a Group Policy minimum length, or a router that will not accept a short admin password. The same three options appear as A, B and C in A4.3 (firewall password) and A5.5 (external services), with D for passwordless and E for none of the above.
With MFA, the password element still has a floor. v3.3 says 'The password element of the multi-factor authentication approach must have a password length of at least 8 characters, with no maximum length restrictions.'
| Option | Minimum length | Also needs | Maximum length |
|---|---|---|---|
| A. Multi-factor authentication | 8 characters | MFA enforced on the account (v3.3 sets no prompt frequency) | None allowed |
| B. Deny list | 8 characters | Automatic blocking of common passwords | None allowed |
| C. Length only | 12 characters | Nothing else | None allowed |
How must passwords be protected against brute-force guessing?
By at least one of MFA, throttling to no more than 10 guesses in 5 minutes, or locking after no more than 10 failed attempts.
Passwords are protected against brute-force password guessing by implementing at least one of: multi-factor authentication (see above); ‘throttling' the rate of attempts, so that the length of time the user must wait between attempts increases with each unsuccessful attempt. You should allow no more than 10 guesses in 5 minutes; locking devices after no more than 10 unsuccessful attempts
MFA counts on its own. Without it, either the wait between attempts must grow with each failure, or the account or device must lock after no more than 10 failures. A7.10 asks which you use, including where a password is the backup for a passwordless sign-in, and A5.7 asks the same for external services that do not use MFA.
Should you force password expiry or complexity?
No. v3.3 lists 'not enforcing regular password expiry' and 'not enforcing password complexity requirements' among the ways to support users.
Support users to choose unique passwords for their work accounts by: educating people about avoiding common passwords, such as a pet's name, common keyboard patterns or passwords they have used elsewhere ... encouraging people to choose longer passwords by promoting the use of multiple words (a minimum of three) ... providing usable secure storage for passwords (for example a password manager or secure locked cabinet) ... not enforcing regular password expiry; not enforcing password complexity requirements
Change a password when you know or suspect it is compromised instead. A7.12 asks how you support people to choose unique, strong passwords: training on the points above, the NCSC's three random words advice and a password manager are the usual answer.
QuestionsA7.12
When must a password be changed?
When you know or suspect it has been compromised, not on a timer.
You should also make sure there is an established process in place to change passwords promptly if you know or suspect a password or account has been compromised.
A7.13 asks whether the process exists. A4.4 asks the same of your firewall password and A5.6 asks you to describe the process for external services. The A4.4 guidance gives two triggers worth writing into the process: a virus on your system, or a manufacturer notifying you of a security weakness in their product.
Do the password rules apply to device PINs?
Only in a lighter form: a credential that only unlocks a device needs a biometric, or a PIN or password of at least 6 characters, and whichever you choose must be protected against brute force.
You must protect your chosen authentication method (which can be biometric authentication, password or PIN) against brute-force attacks.
If credentials are just to unlock a device, use a minimum password or PIN length of at least 6 characters. When the device unlocking credentials are also used for authentication, you must apply the full password requirements to the credentials described in User Access Controls.
Where the vendor does not let you configure throttling or lockout, v3.3 says to use the vendor's default setting. If the same credential also signs in to organisational services, the full rules above apply. A5.10 asks which unlock method you use.
Windows Hello. Microsoft's Windows Hello for Business policy reference says that if the Minimum PIN length policy is not configured, 'the PIN length must be greater than or equal to 6', and the lowest value you can set is 4. Leave it unset or set it to 6 or more: Computer Configuration > Administrative Templates > System > PIN Complexity > Minimum PIN length, or the PassportForWork PINComplexity MinimumPINLength setting in Intune.
Phones and tablets. Set a passcode policy with a minimum length of 6 through your device management tool. In the free Basic Mobility and Security, Microsoft documents that only Samsung Knox devices on Android 9.0 or later support password settings, so other Android phones need Intune or another MDM, or a documented manual check.
Which questions ask about passwords?
Eleven questions across three sections touch password rules, and none carries automatic fail wording. In our assessments an answer that does not meet the rule is returned for correction.
| Question | Covers | Answer type |
|---|---|---|
| A4.3 | Firewall password quality (options A to E) | Options |
| A4.4 | Changing the firewall password if compromised | Yes/No |
| A5.3 | Default passwords changed on devices | Yes/No |
| A5.5 | Authentication option for external services | Options |
| A5.6 | Process for changing compromised external service passwords | Notes |
| A5.7 | Brute-force protection for external services without MFA | Options |
| A5.10 | Device unlock method | Notes |
| A7.10 | Brute-force protection for passwords | Notes |
| A7.11 | Technical controls for password quality | Notes |
| A7.12 | How you encourage unique, strong passwords | Notes |
| A7.13 | Process for compromised passwords or accounts | Yes/No |
Did the password rules change in 2026?
The thresholds did not: v3.3 keeps the same 12-character, 8-plus-deny-list and 10-attempt rule set. Two things moved. The passwordless definition now names FIDO2 authenticators, regarded as MFA. In the question set, option D in A4.3 and A5.5 is now passwordless and option E is 'none of the above', and both need a notes description. See what changed in Danzell.
How do you meet the rules in Microsoft 365, Windows and on a router?
Enforce MFA in Microsoft 365, set a lockout threshold of 10 or fewer on Windows, and give router and firewall admin logins a password that meets option B or C, or MFA.
Microsoft 365 and Entra ID. Microsoft documents that cloud-only Entra ID passwords need at least 8 and at most 256 characters, and that the global banned password list is applied 'when they change or reset their own password through Microsoft Entra ID'. For users synchronised from on-premises Active Directory, Microsoft lists Entra ID P1 or P2 as the licence for banned password protection. Smart lockout is on for every tenant and locks an account after 10 failed attempts by default in commercial tenants. With MFA enforced for everyone, option A covers A7.11 and A7.10 together.
Windows devices. Set the lockout under Computer Configuration > Windows Settings > Security Settings > Account Policies > Account Lockout Policy, with an account lockout threshold of 10 or fewer, and set the minimum length under Account Policies > Password Policy. Microsoft's reference page lists the client default for the lockout threshold as 0, which never locks, so set it explicitly. The Windows 11 setup guide has the paths.
Routers and firewalls. Change the default admin password to one that meets option C (12 characters or more) or option B (8 characters with a deny list, if the device has one), or use MFA for the admin login where the device supports it. The DrayTek and FortiGate guides show where each setting lives.
What should you write in the A7.11 notes field?
A7.11 asks which technical controls manage password quality. Name the option, the system that enforces it and any exceptions. A model you can adapt:
All staff sign in to Microsoft 365 with cloud-only Entra ID accounts, and Conditional Access requires MFA for every user and administrator on all cloud apps (option A). Entra ID enforces a minimum password length of 8 characters and checks new passwords against Microsoft's global banned password list. Windows laptops are Entra-joined and use Windows Hello for Business, which signs in to Entra ID as an MFA method; the PIN minimum is left at Microsoft's default of 6. Local accounts are disabled. The office firewall admin password is 16 characters, generated in our password manager. We do not enforce password expiry; passwords are changed when we suspect compromise (see A7.13).
How do assessors check password answers?
Related requirements
- User access control requirementsThe control hub: every A7 requirement
- A7.11: password quality controlsWhich option you enforce
- A7.10: brute-force protectionThrottling, lockout or MFA
- A7.13: compromised passwordsThe change-on-compromise process
- Cyber Essentials MFA requirementsMandatory on every cloud service
- Cyber Essentials admin account requirementsSeparate accounts for admin tasks only
- A4.3: firewall passwordThe same options for router admin logins
- Glossary: device unlockingThe 6-character rule
- Glossary: brute-force attackWhat throttling and lockout stop
- Check your readinessTest your answers against the auto-fail questions first
Frequently asked questions
It depends on the option. With MFA the password element must be at least 8 characters. Without MFA, either 12 characters, or 8 characters with automatic blocking of common passwords using a deny list. A PIN or password used only to unlock a device needs at least 6 characters.
Not a low one. Every password option in v3.3 says 'no maximum length restrictions', so a system that caps passwords at, say, 16 characters does not meet the wording. Our interpretation: a very high technical limit, such as Entra ID's 256 characters, is not what the rule targets, but say so in your notes if your platform has one.
Without MFA, no more than 10. v3.3 offers throttling that allows no more than 10 guesses in 5 minutes, with the wait increasing after each failure, or locking after no more than 10 unsuccessful attempts. MFA on its own also meets the brute-force requirement.
A list of known weak or breached passwords that the system refuses at creation or change. With a deny list, an 8-character minimum meets the rule. Microsoft Entra ID applies a global banned password list to cloud accounts when users change or reset their password, and some password managers and identity providers offer the same check.
A password manager helps users meet the rules but is not a technical control by itself. v3.3 lists secure storage, such as a password manager, as a way to support users. The system they sign in to must still enforce one of the three quality options.
No. v3.3 says a credential used only to unlock a device needs a minimum password or PIN length of at least 6 characters, or a biometric, protected against brute force. Set a 6-digit minimum through your device management tool, or check each phone by hand and record it.
- NCSCCyber Essentials: Requirements for IT Infrastructure v3.3 · April 2026Read on ncsc.gov.uk (opens in a new tab)
- IASMECyber Essentials Danzell Question Set 2026Read on iasme.co.uk (opens in a new tab)
- NCSCCyber Essentials Plus Test Specification v3.2Read on ncsc.gov.uk (opens in a new tab)
- NCSCThree random wordsRead on ncsc.gov.uk (opens in a new tab)
- Microsoft LearnCombined password policy and check for weak passwords in Microsoft Entra ID · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnPassword protection in Microsoft Entra ID (global banned password list) · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnPrevent attacks using smart lockout · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnAccount lockout threshold (Windows) · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnWindows Hello for Business policy settings (PIN complexity) · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnMicrosoft Entra multifactor authentication versions and licensing · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)
- Microsoft LearnOverview of Basic Mobility and Security · Checked 9 November 2026Read on learn.microsoft.com (opens in a new tab)