title: "Printers, phones, CCTV and smart devices in Cyber Essentials scope"
description: "Are printers, VoIP phones and CCTV in Cyber Essentials scope? What v3.3 says, how sub-sets work, and the default password and firmware rules that apply."
url: https://cyberessentialspreparation.com/requirements/scope/printers-iot-and-smart-devices
markdown: https://cyberessentialspreparation.com/requirements/scope/printers-iot-and-smart-devices.md
datePublished: 2026-11-09
dateModified: 2026-11-09
lastReviewed: 2026-11-09
author: "Precursor Security"
publisher: Precursor Security
licence: "Site content © Precursor Security. Cyber Essentials requirement text is Crown copyright, Open Government Licence v3.0."
---
# Printers, phones, CCTV and smart devices in Cyber Essentials scope

> Are printers, VoIP phones and CCTV in Cyber Essentials scope? What v3.3 says, how sub-sets work, and the default password and firmware rules that apply.

## Short answer

Printers are out of scope for Cyber Essentials. IASME's scope FAQ answers 'No, printers are not deemed to be in the scope of Cyber Essentials', and v3.3 never names them. A printer's cloud portal can still be a cloud service (A2.9) and a port forward to it is an inbound rule (A4.8). Other smart devices follow the v3.3 scope test.

## Key facts

| Fact | Detail |
| --- | --- |
| Printers | Out of scope. IASME Knowledge Hub scope FAQ: 'No, printers are not deemed to be in the scope of Cyber Essentials' (checked 9 November 2026) |
| Named in v3.3? | No. The requirements and the Danzell question set do not mention printers, CCTV, smart TVs or IoT |
| CCTV, VoIP handsets, building systems | No IASME answer found. Our interpretation: the v3.3 scope test applies, so secure them or segregate them |
| Removing devices from scope | A sub-set segregated by a firewall or VLAN. Security groups, microsegmentation and software-based methods are not compliant (A2.2.2 guidance) |
| Default passwords | Required on every in-scope device (v3.3 Secure Configuration). Good practice on printers and on devices segregated out of scope |
| Cloud portals | Management portals for cameras, printers, phones and door access are cloud services if accessed by an account and storing or processing your data |
| Questions | [A2.1](https://cyberessentialspreparation.com/questions/scope/a2-1), [A2.2.1](https://cyberessentialspreparation.com/questions/scope/a2-2-1), [A2.2.2](https://cyberessentialspreparation.com/questions/scope/a2-2-2), [A2.4](https://cyberessentialspreparation.com/questions/scope/a2-4), [A2.5.1](https://cyberessentialspreparation.com/questions/scope/a2-5-1), [A2.9](https://cyberessentialspreparation.com/questions/scope/a2-9), [A4.8](https://cyberessentialspreparation.com/questions/firewalls/a4-8) |
| Source | Requirements for IT Infrastructure v3.3, Sections B and D, Definitions and Scope |

## Are printers in scope for Cyber Essentials?

No. IASME, which runs Cyber Essentials, answers the question directly in its [Knowledge Hub scope FAQ](https://iasme.atlassian.net/wiki/spaces/CEKH/pages/2576974115/Scope+FAQ) (page updated 12 February 2026, checked 9 November 2026): 'No, printers are not deemed to be in the scope of Cyber Essentials.' An [earlier Knowledge Hub answer](https://iasme.atlassian.net/wiki/x/awB5n) (October 2023, checked 9 November 2026) adds: 'Printers are not mentioned in the CE requirements and are considered out of scope of the assessment. CE+ absolutely allows printing from home computers/VDI.'

So you do not list printers or multifunction devices in the question set, and they are not a reason to declare a partial scope. Three things around a printer can still be in scope. The computers and servers that print to it are. A cloud print or fleet management portal that your staff sign in to is a cloud service if it meets the v3.3 definition, so it goes in A2.9 with MFA. And a port forward through your boundary firewall to a printer is an inbound connection that A4.8 asks you to approve and document.

## What does v3.3 say about smart devices?

Nothing by name: v3.3 never uses the words printer, CCTV, camera or IoT, and no Danzell question asks you to list them. It does give definitions and one scope test that settle most cases.

-   Devices 'includes all types of hosts, networking equipment, servers, networks, and end user devices such as desktop computers, laptops, thin clients, tablets and smartphones - whether physical or virtual'.
-   Software includes 'operating systems, commercial off-the-shelf applications, extensions, interpreters, scripts, libraries, network software and firewall and router firmware'.
-   Organisational service lists examples including web applications, Microsoft 365, Citrix Desktop and IP telephony.
-   A cloud service is an on-demand, scalable service on shared infrastructure, accessed over the internet through an account, that stores or processes data for your organisation.
-   The requirements apply to all devices and software in scope which can accept incoming network connections from internet-connected devices, can establish outbound connections to devices via the internet, or control the flow of data between those devices and the internet.

## Are CCTV cameras, VoIP phones and building systems in scope?

IASME's Knowledge Hub gives no answer for these devices (we searched it on 9 November 2026), so the v3.3 scope test decides, and how it applies to them is our interpretation rather than an IASME ruling. The 'Applies to' line of each control names servers, desktop computers, laptops, tablets, mobile phones, thin clients, boundary firewalls, routers, IaaS, PaaS and SaaS, and none of these devices is on those lists.

Our interpretation: a camera, phone handset or building controller on an in-scope network that can reach the internet meets the v3.3 scope test even though no control names its type, so the choices are to secure it or to segregate it. v3.3 says you must agree the scope with the Certification Body before assessment begins, so raise these devices then.

How common non-computer devices fit the v3.3 scope rules. The printer and switch rows are IASME's Knowledge Hub answers; every other row is our interpretation, not an official NCSC or IASME table.

| Device type | In scope when | Typical fix |
| --- | --- | --- |
| Network printers and multifunction devices | Not in scope: IASME says printers 'are not deemed to be in the scope of Cyber Essentials' | Nothing to declare. Good practice: change the default admin password and keep firmware supported |
| Network switches | IASME's scope FAQ answers 'No'. The A2.5 guidance asks you to list a switch only if it contains a firewall or routes internet traffic | List in A2.5 only if it does either |
| VoIP desk phones | The handset is on an in-scope network and reaches the internet; the hosted telephony platform is an organisational service (IP telephony) and, if it meets the definition, a cloud service | List the telephony platform in A2.9 with MFA enforced; change default handset admin PINs; apply firmware through the provider's provisioning |
| CCTV cameras and NVRs | A port forward or vendor cloud app gives remote viewing, which means inbound or outbound internet connections | Remove port forwards or approve and document them (A4.8); change default passwords; update firmware; or segregate on a VLAN |
| Smart TVs and meeting-room displays | They connect to the internet for apps, casting or updates while on an in-scope network | Segregate them on a separate VLAN or behind a firewall (a guest Wi-Fi network only counts if it is one of those), remove unused apps, and turn on automatic updates |
| Door access and building management | Controllers are cloud-managed or the vendor has remote access through your firewall | Treat the management portal as a cloud service with MFA; document any inbound rule for vendor access; segregate the controllers |

## How do I take smart devices out of scope with a sub-set?

With a firewall or a VLAN and nothing else. v3.3 defines a sub-set as 'part of the organisation whose network is segregated from the rest of the organisation by a firewall or VLAN', and the A2.2.2 guidance adds: 'Sub-sets must be created using a firewall or VLAN - other methods such as security groups, microsegmentation or software-based methods are not compliant.' IASME's scope FAQ adds that segregation 'must be done at Layer 2 or Layer 3 of the OSI model'. A2.5.1 asks you to list the routers, physical firewalls or virtual firewalls used to create sub-sets, and notes that software firewalls built into operating systems cannot define the scope boundary.

There are consequences. The A2.1 guidance says a partial organisation means some networks are excluded from scope, and v3.3 says you will need to justify a partial scope to your assessor. A2.2 notes that a partial certificate's scope description will read 'Partial Organisation, see certificate platform for details'. If the devices you are excluding run unsupported firmware, v3.3 is stricter: unsupported software must be removed, or removed from scope by using a defined sub-set that prevents all traffic to or from the internet. IASME's scope FAQ defines that: 'No internet access means that all inbound and outbound connections must be blocked at the boundary of the segregated network.' A camera VLAN that still reaches the vendor's cloud does not meet that test.

Our interpretation: for most small organisations it is simpler to keep cameras and phones in a whole-organisation scope on their own VLAN, with passwords changed and firmware updated, than to declare a partial scope. See [sub-set](https://cyberessentialspreparation.com/glossary/sub-set) and [VLAN](https://cyberessentialspreparation.com/glossary/vlan) in the glossary.

## Do default passwords on smart devices matter?

Yes for any device that is in scope, and as good practice for printers and segregated devices. The secure configuration control is written for 'computers and network devices' and says you must regularly change any default or guessable account passwords and remove or disable unnecessary software, including network services. It warns that out-of-the-box configurations often include 'an administrative account with a pre-set, publicly known default password', which describes most NVRs, IP phones and printers as delivered.

The scheme requires it for routers, firewalls and any camera, phone or controller you keep in scope. For printers, which IASME treats as out of scope, and for devices on a segregated sub-set, it is recommended, not required: change the admin password to a unique one in your password manager and turn off web, Telnet, FTP and SNMP services you do not use. See [default password](https://cyberessentialspreparation.com/glossary/default-password).

## Does smart device firmware need updating within 14 days?

The requirements set the 14-day rule explicitly only for router and firewall firmware; for cameras, phones and other smart devices it applies only if the device is in scope, and printers are out of scope. A6.1 says the firmware of firewall or router devices in scope 'is considered to be an operating system', and A6.4 says the 14-day rule for high-risk or critical fixes 'includes the firmware on your firewalls and routers'. A No to A6.4 is an automatic fail.

Our interpretation: if a camera, phone or building controller is in scope, its firmware is software on an in-scope device and meets the same rule: vendor-supported, with critical fixes applied within 14 days. The A6.3 guidance warns that for some operating systems, firmware and applications, updates stop if annual licensing is not purchased, which is common with NVR and building management software. Where such a device has reached end of support, replace it or move it into a sub-set that blocks all traffic to or from the internet. See [firmware](https://cyberessentialspreparation.com/glossary/firmware).

## Will a Cyber Essentials Plus assessor test printers and cameras?

Not in the device sample, but the external scan can find them. The CE Plus Test Specification v3.2 applies its sampled tests to 'end user devices (EUDs) that can connect to organisational data or services', 'all internally hosted servers' and 'all types of cloud service', and printers, cameras and phone handsets are none of those. Test case 1, the external vulnerability scan, covers 'all IP addresses associated with the Applicant', so a printer or NVR exposed through a port forward will show up and be judged like any other exposed service.

## How do I describe smart devices in the question set?

Printers are not listed at all; other smart devices appear in up to four places, because there is no device-count question for them. A2.4 asks for each network by name, location and purpose, so an in-scope 'Building systems VLAN at head office for CCTV and door access' belongs there. If you exclude it instead, describe it in A2.2.1, explain the method in A2.2.2 (for example 'IoT network, segregated by VLAN') and list the enforcing firewall or router in A2.5.1. Vendor portals for cloud cameras, cloud print, hosted telephony and door access go in A2.9, and the MFA questions A7.16 and A7.17 then apply to them. Any port forward for remote viewing belongs in the A4.8 description of approved inbound connections, with the business need.

## How do assessors check smart devices and printers in scope?

**What they look for**

Assessors look for consistency. A2.4 networks should match the A2.5 equipment list; a sub-set in A2.2.1 needs a firewall or VLAN in A2.2.2 and a device in A2.5.1; and an organisation that mentions remote CCTV viewing or cloud-managed door access should show the matching inbound rule in A4.8 or portal in A2.9. Printers are not expected in the answers, in line with IASME's scope FAQ. On Cyber Essentials Plus, test case 1 scans every IP address associated with the applicant, so a camera, NVR or printer exposed through a port forward will be found.

**Common failure: The port-forwarded CCTV recorder**

An office answers No to A4.7 and describes no inbound rules in A4.8, but the installer set up a port forward years ago so the manager can view cameras on a phone. The NVR runs old firmware with the default admin password. The external scan in Cyber Essentials Plus test case 1 finds it. Fix: remove the port forward and use the vendor's cloud app or your VPN instead, change the password, update the firmware, and move the cameras to their own VLAN.

## Related requirements

-   [**Scope overview**](https://cyberessentialspreparation.com/requirements/scope)
-   [**Wireless devices and access points**](https://cyberessentialspreparation.com/requirements/scope/wireless-devices)
-   [**A2.2.2: how sub-sets are created**](https://cyberessentialspreparation.com/questions/scope/a2-2-2)
-   [**A2.5.1: equipment used to create sub-sets**](https://cyberessentialspreparation.com/questions/scope/a2-5-1)
-   [**Secure configuration requirements**](https://cyberessentialspreparation.com/requirements/secure-configuration)
-   [**Security update management**](https://cyberessentialspreparation.com/requirements/security-update-management)
-   [**Glossary: sub-set**](https://cyberessentialspreparation.com/glossary/sub-set)
-   [**Glossary: port forwarding**](https://cyberessentialspreparation.com/glossary/port-forwarding)
-   [**Check your readiness** Test your scope and controls against the auto-fail questions](https://cyberessentialspreparation.com/tools/assessment-checker)

## Frequently asked questions

### Do I need to list printers in the Cyber Essentials question set?

No. IASME's Knowledge Hub says printers are not deemed to be in the scope of Cyber Essentials, and no Danzell question asks for them. List a cloud print portal in A2.9 if staff sign in to it, and document any port forward to a printer at A4.8. Changing the printer's default password is still good practice.

### Are VoIP desk phones in scope?

IASME gives no answer on handsets. v3.3 names IP telephony as an example of an organisational service, and our interpretation is that a hosted phone system that stores your call data behind an account is a cloud service, so list it in A2.9 with MFA. Change default handset admin PINs and keep firmware updated.

### Can I put IoT devices on a separate VLAN to remove them from scope?

Yes, a VLAN or firewall is the only compliant way to create a sub-set, and a guest Wi-Fi network only counts if it is one of those. Excluding a network makes your certificate a partial-organisation scope, which you describe in A2.2.1 and A2.2.2 and justify to the assessor. If the devices run unsupported software, the sub-set must block all traffic to or from the internet.

### Do security groups or Windows Firewall rules count as segregation?

No. The A2.2.2 guidance says security groups, microsegmentation and software-based methods are not compliant for creating sub-sets, and A2.5.1 says software firewalls built into operating systems cannot define the boundary of the scope.

### Is a cloud camera or door access portal a cloud service?

If it is accessed through an account and stores or processes data for your organisation, it meets the v3.3 cloud service definition. Cloud services cannot be excluded from scope, so list it in A2.9 and enforce MFA where the service offers it.

## Would you pass the 2026 question set?

Answer 24 yes or no questions, built by Precursor Security, an IASME Cyber Essentials Certification Body, and get a readiness score in about five minutes, with any auto-fail questions you miss flagged first in your results.

[Check your readiness](https://cyberessentialspreparation.com/tools/assessment-checker), [Book a gap analysis, from £500](https://cyberessentialspreparation.com/gap-analysis)

-   IASME Certification Body
-   CREST accredited
-   UK offices in Leeds, Newcastle, London and Edinburgh

Sources

-   [NCSC Cyber Essentials: Requirements for IT Infrastructure v3.3 · April 2026 Read on ncsc.gov.uk](https://www.ncsc.gov.uk/files/cyber-essentials-requirements-for-it-infrastructure-v3-3.pdf)
-   [IASME Cyber Essentials Danzell Question Set 2026 Read on iasme.co.uk](https://iasme.co.uk/cyber-essentials/preview-the-self-assessment-questions-for-cyber-essentials/)
-   [iasme.atlassian.net IASME Knowledge Hub, Scope FAQ · Checked 9 November 2026 Read on iasme.atlassian.net](https://iasme.atlassian.net/wiki/spaces/CEKH/pages/2576974115/Scope+FAQ)
-   [NCSC Cyber Essentials Plus Test Specification v3.2 Read on ncsc.gov.uk](https://www.ncsc.gov.uk/sites/default/files/2026-05/cyber-essentials-plus-test-specification-v3-2%20english.pdf)


---

## About the publisher
This site is run by Precursor Security Ltd (company 11234631, founded 2018, headquartered in Leeds), an IASME Cyber Essentials Certification Body and CREST-accredited UK firm. As a Certification Body, Precursor assesses Cyber Essentials self-assessments and runs Cyber Essentials Plus audits itself, and certificates are issued through IASME; no separate consultant is needed.

- Cyber Essentials: from £1,500 + VAT, IASME fee included, typically 1 to 2 weeks.
- Cyber Essentials Plus: from £3,000 + VAT (from £4,500 for 250+ staff), Cyber Essentials self-assessment and IASME fee included.
- Gap analysis before you submit: from £500 + VAT, 1 to 3 days.
- Also: CREST-accredited penetration testing and SOC, and ISO 27001 consultancy (https://www.precursorsecurity.com).
- Prices are Precursor's published prices (https://www.precursorsecurity.com/services/compliance/cyber-essentials-certification/cost), checked 2026-11-09.
- Help by question (getting certified, Basic or Plus, cost, after a fail, customer deadlines, ISO 27001 and pen tests): https://cyberessentialspreparation.com/help (markdown: https://cyberessentialspreparation.com/help.md).
- Contact: +44 113 486 4873, info@precursorsecurity.com, https://cyberessentialspreparation.com/contact. Fixed-price quote: https://cyberessentialspreparation.com/get-certified#quote.
- Any IASME licensed Certification Body issues the same certificate; IASME lists them all at https://iasme.co.uk/cyber-essentials/find-a-certification-body/. The guides on this site are free whoever certifies you.